PERFORMANCE AND RELIABILITY IS OUR BUSINESS

Signal Conditioners, Transmitters, Isolators, Converters

Buy online from The Sensor Connection today. We ship Worldwide!

Signal Conditioners, Transmitters, Voltage Isolators, Converters for Industrial, Process, and OEM custom applications

8-Channel Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog Output

• Thermocouple Input: Type K (8 independent input channels)
• Linearized Analog Output: 0 to 5 VDC (8 independent output channels)
• Supply Voltage: 10 to 28 VDC
• On-board CJC
• Includes (8) mini-plug signal input connectors
• Includes detachable signal output/power wiring harness
• Compact Size, only 7.0" x 3.5" x 1.6"

8-Channel Type K Thermocouple Amplifier Signal Conditioner Module 0 to 5 VDC Out
$389.00
View Product Detail Page

APD 4393 - DC to DC Isolated Signal Splitter Transmitter

• 1 Input, 2 Independent Outputs
• DC Voltage Input: 0-10 mV to 0-100 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 50 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

APD 4393 - DC to DC Isolated Signal Splitter Transmitter
$459.00
View Product Detail Page

API 4300G - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 mV to 0-500 V
• DC Bipolar Voltage Input: +/- 100 mV to +/- 10 V
• DC Current Input 0-1 mA to 900 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API 4300 DC to DC Transmitter Module
$289.00
View Product Detail Page

API 1000G - DC Input to Single Setpoint Alarm Trip

• DC Voltage Input: 0-100 mV to 0-300 VDC
• DC Current Input: 0-1 mA to 900 mADC
• Output: (1) DPDT Relay
• Factory Pre-Configured

API 1000G DC Input to Alarm Trip Module
$219.00
View Product Detail Page

APD 4300 - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 mV to 0-300 V
• DC Bipolar Voltage Input: +/- 100 mV to +/- 10 V
• DC Current Input 0-1 mA to 900 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API APD-4300 PLC DC to DC Transmitter Module
$299.00
View Product Detail Page

APD HV-DC - High Voltage - DC to DC Isolated Transmitter

• DC Voltage Input: 0-100 V to 0-1200 V
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API APD HV-DC High Voltage DC to DC Isolated Transmitter Field Configurable
$379.00
View Product Detail Page

API 1090G DC Input to Dual Setpoint Alarm Trip - Field Configurable

• 26 field configurable input ranges
• DC Voltage Input: 0-50 mV to +/- 10 V
• DC Current Input: 0-1 mA to 0-20 mA
• Output: (2) SPDT Relays
• Field-Configurable by User

API 1090G DC Input to Alarm Trip Module
$249.00
View Product Detail Page

API 1020G - DC Input to Dual Setpoint Alarm Trip

• DC Voltage Input: 0-100 mV to 0-300 VDC
• DC Current Input: 0-1 mA to 900 mADC
• Output: (2) SPDT Relays
• Factory Pre-Configured

API 1020G DC Input to Alarm Trip Module
$249.00
View Product Detail Page

API 4380G - DC to DC Isolated Transmitter - Field Configurable

• DC Voltage Input: 0-50 mV to 0-10 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 20 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API 4380G DC to DC Transmitter Field Configurable
$289.00
View Product Detail Page

API 4385G - DC to DC Isolated Transmitter - Field Configurable - NIZSP

• DC Voltage Input: 0-50 mV to 0-20 V
• DC Bipolar Voltage Input: +/- 50 mV to +/- 10 V
• DC Current Input 0-1 mA to 20 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User
• Non-Interactive Zero & Span Adjustment Pots

API 4385G DC to DC Transmitter Field Configurable
$319.00
View Product Detail Page

API 1720G - Frequency Input to Dual Setpoint Alarm Trip

• Frequency Input: 0-10 Hz to 0-20 kHz
• Output: (2) SPDT Relays
• Factory Pre-Configured

API 1720G DC Input to Alarm Trip Module
$279.00
View Product Detail Page

API 7010G - Frequency to DC Isolated Transmitter

• Frequency Input: 0-25 Hz to 0-20 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

API 7010G Frequency to DC Transmitter Module
$309.00
View Product Detail Page

API 1080G DC Input to Single Setpoint Alarm Trip - Field Configurable

• 24 field configurable input ranges
• DC Voltage Input: 0-50 mV to +/- 10 V
• DC Current Input: 0-1 mA to 0-20 mA
• Output: (1) DPDT Relay
• Field-Configurable by User

API 1080G DC Input to Alarm Trip Module
$219.00
View Product Detail Page

API 1700G - Frequency Input to Single Setpoint Alarm Trip

• Frequency Input: 0-10 Hz to 0-20 kHz
• Output: (1) DPDT Relay
• Factory Pre-Configured

API 1700G DC Input to Alarm Trip Module
$259.00
View Product Detail Page

APD 7010 - Frequency to DC Isolated Transmitter

• Frequency Input: 0-25 Hz to 0-20 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

APD 7010G Frequency to DC Transmitter Module
$329.00
View Product Detail Page

Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog Output

• Thermocouple Input: Type K
• Linearized Analog Output: 0 to 5 VDC
• Supply Voltage: 10 to 28 VDC
• On-board CJC
• Quick Connection via Mini-Thermocouple Plug (included)
• Compact Size, only 2.5" x 2.5" x 0.9"

Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog O
$78.25
View Product Detail Page

API 7580G - Frequency to DC Isolated Transmitter - Field Configurable

• Frequency Input: 0-100 Hz to 0-30 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

API 7580G Frequency to DC Transmitter Field Configurable
$319.00
View Product Detail Page

API 4059G - Strain Gauge Bridge/Load Cell to DC Transmitter - Field Configurable - Isolated

• DC Voltage Input: 0-5 mV to 0-400 mV
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Strain Gauge Bridge Excitation: 1 to 10 VDC
• Field-Configurable by User
• Non-Interactive Zero & Span Adjustment Pots

API 4059G Strain Gauge to DC Transmitter Field Configurable
$339.00
View Product Detail Page

APD 7580G - Frequency to DC Isolated Transmitter - Field Configurable

• Frequency Input: 0-100 Hz to 0-30 kHz
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

APD 7580G Frequency to DC Transmitter Field Configurable
$339.00
View Product Detail Page

APD 1500 Series - Strain Gauge/Load Cell Transducer Input to Setpoint Alarm Trip

• DC Voltage Input: 0-5 mV to 0-2000 mV DC
• Output: (1) SPDT Relay HI alarm (model APD 1500)
• Output: (2) SPDT Relays HI/LO alarm (model APD 1520)
• Output: (2) SPDT Relays for Band Alarm (model APD 1530)
• Strain Gauge Bridge Excitation: 1 to 10 VDC
• Factory Pre-Configured

APD 1500 Strain Gauge Transducer Input to Setpoint Alarm Trip
$279.00
View Product Detail Page