•  Welcome Guest
  • Login
  • Register
Call Us  248-636-1515
  • 0 items
  • Total: $0.00
  • View Cart
  • Checkout

PERFORMANCE AND RELIABILITY IS OUR BUSINESS

Motorsports

  • EGT Probes
    • Gas
    • Diesel
    • 2-Stroke
    • Extreme Duty Racing
    • All EGT Probes
  • EGT Electronics
    • Meters / Displays
    • Meter Kits
    • Gauges
    • Amplifiers
    • All EGT Electronics
  • EGT Accessories
    • Compression Fittings and Mounting Hardware
    • Connectors
    • Extension Wire
    • Weld Bungs
    • All EGT Accessories
  • CHT Sensors
    • Electronics
    • Accessories
    • All CHT Sensors
  • Gauges / Pyrometers
    • Single Channel
    • Multi-channel
    • All Gauges / Pyrometers
  • Gauge / Pyrometer Kits
    • Single Channel
    • Multi-channel
    • Round Digital Gauge Kits
    • Rectangular Digital Gauge Kits
    • Handheld Digital Gauge Kits
    • Round Analog Gauge Kits
    • Gas Engines Gauge Kits
    • Diesel Engine Gauge Kits
    • Marine Gauge Kits
    • Motor Home Gauge Kits
    • Snowmobile Gauge Kits
    • All Gauge / Pyrometer Kits
  • Belt Temperature
  • Brake Sensors
    • All Brake Sensors
  • Fluid Temperature
    • All Fluid Temperature
  • Linear Travel Sensors
  • Motorsports Tech Notes
    • EGT Tech Notes
      • Why Use our Probes?
      • Thermocouple Wire Color Chart
      • Thermocouple Compatibility List
      • EGT Probe Performance tuning Installation and Information
      • ITS-90 Thermocouple Correction Tables
      • What is a Thermocouple
      • EGT Diesel Engine Installation Information
    • CHT Tech Notes
  • Motorsports FAQ
    • EGT FAQs
    • CHT FAQs
  • Sale Items

Industrial Products

  • Thermocouples
    • Electronics
    • Accessories
    • All Thermocouples
  • RTDs
  • LVDT Position Sensors
    • Spring Loaded
      • AC
      • DC
      • 2-wire 4-20mA
    • Free Core
      • AC
      • DC
      • 2-wire 4-20mA
    • Accessories
    • All LVDT Position Sensors
  • LVDT Electronics
    • Electronics
    • All LVDT Electronics
  • Signal Conditioners
    • DC Input
      • DC Input to Alarms
      • DC Input to DC Output
      • DC Input to Frequency Output
    • Frequency Input
      • Frequency Input to Alarms
      • Frequency Input to DC Output
    • Strain Gauge / Load Cell Input
      • Strain Gauge Input to Alarms
      • Strain Gauge Input to DC Output
    • Temperature Input
      • Thermocouple Input to Alarms
      • Thermocouple Input to DC Output
      • RTD Input to Alarms
      • RTD Input to DC Output
    • All Signal Conditioners
  • Instrumentation
    • Meters / Displays
  • Rotary Sensors
    • Electronics
    • Accessories
    • All Rotary Sensors
  • Linear Position Sensors
  • Pressure Transducers
  • Suco Pressure Switches
  • Cable Assemblies
  • Custom Products
  • Industrial Tech Notes
    • LVDT Tech Notes
    • Signal Conditioner Tech Notes
    • Position Sensors Tech Notes
    • All Industrial Tech Notes
  • Industrial FAQ
    • LVDT FAQs
    • Signal Conditioner FAQs
    • Position Sensors FAQs
    • All Industrial FAQ
  • Sale Products

Find Sensors and Electronics by Application

  • Motorsports
    • Gas Racing
      • Racing Drag / Road/ Circle
      • Motorcycles / Drag / Road / Circle
      • Small Engines
    • Diesel & Bio Fuel
      • Trucks / Towing
      • Heavy Truck / Agricultural
      • Power Gen EGT
    • Marine
      • Marine Diesel
      • Marine Gas
    • Aircraft
      • Small Aircraft Engines
      • Ultralite
    • Commercial
      • Barbecue / Smokers
      • Flu / Heater / Furnaces
      • HVAC
  • Industrial
    • Factory Automation
    • Energy and Power Gen
    • Industrial OEM
    • Hydraulics / Pneumatics
    • Aerospace / Military
    • Civil Engineering

Technical Info

  • Manuals & Datasheets
    • LVDT
      • Catalogs
        • LVDT Short Form Catalogs
        • LVDT Full Detail Catalogs
    • EGT Probes
      • Catalogs
        • EGT Probe Short Form Catalogs
        • EGT Probe Full Detail Catalogs
  • Horsepower Calculators
    • Horsepower
    • Engine Displacement
  • Racing Weather
  • Blogs
    • LVDT Blog
    • EGT Probe Blogs
  • Videos

Corporate Info

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases
Home » Signal Conditioners

APD HV-DC - High Voltage - DC to DC Isolated Transmitter

API APD HV-DC High Voltage DC to DC Isolated Transmitter Field Configurable
Sale Price:
$469.00
SKU: APD-HV-DC
Availability: 1 week
Quantity:

Options

Choose module power options

Product Info:

  • Summary
  • Technical
  • Video

• DC Voltage Input: 0-100 V to 0-1200 V
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Field-Configurable by User

Lead-time: Typically ships within 2 to 3 business days

CLICK on Technical Tab to download data sheet with full technical details

Made in the USA

Input
Field Rangeable; Via external rotary & slide switches
8 User selectable ranges:
0-100 VDC
0-200 VDC
0-300 VDC
0-400 VDC
0-500 VDC
0-1000 VDC
0-1200 VDC
Custom—consult factory for custom range

Output
Field Rangeable; Via external rotary & slide switches
Voltage: 0-1 VDC to 0-10 VDC
or
Bipolar Voltage: +/- 1 VDC to +/- 10 VDC
or
Current (20 V compliance): 0-1 mADC to 0-20 mADC

Isolation
Full 1200 Vrms Input/Output/Power Isolation

Features
1 minute setup of I/O ranges
I/O LoopTracker LEDs
Output test button
20 V loop power supply
60 to 285 VAC powered
D option for 9-30 VDC power

Applications
DC Motor and Variable Speed Drives
Electric Railway Voltages
Power Supply and Voltage Converters
High Voltage Battery Systems

Brand Name: API Absolute Process Instruments
Made in: USA

Datasheet:
application/pdf iconapd_hvdc.pdf

 

 
The API DPI HV-DC accepts a DC voltage input and provides an optically isolated DC voltage or current output that is linearly related to the input. This module is unique because it is field rangeable for voltage inputs from 100 VDC to 1200 VDC. Typical applications include signal isolation and signal conversion.
 
Isolation 
The optical isolation between input and output makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction. The module power supply is isolated, resulting in full 3-way (input, output, power) isolation.
 
Fast Field Setup
The API DPI HV-DC input and output range settings can be reconfigured in the field via external switches. Common range settings are on the module label. A user specified range is available that can be factory configured to meet your specific requirements. Consult the factory for assistance.

Harold G. Schaevitz Industries LLC

The Sensor Connection

World Headquarters

43996 Woodward Avenue

Suite 200

Bloomfield Hills, MI 48302

Phone: 248-636-1515  

Fax: 248-636-4969

CORPORATE

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases

MY ACCOUNT

  • Checkout
  • Login
  • Register
  • View Cart
© Copyright 2021.
All Rights Reserved.
PayPal
Credit Cards
 Network Solutions Seal
website by jhoward.org
[Jump to Top] [Jump to Main Content]