•  Welcome Guest
  • Login
  • Register
Call Us  248-636-1515
  • 0 items
  • Total: $0.00
  • View Cart
  • Checkout

PERFORMANCE AND RELIABILITY IS OUR BUSINESS

Motorsports

  • EGT Probes
    • Gas
    • Diesel
    • 2-Stroke
    • Extreme Duty Racing
    • All EGT Probes
  • EGT Electronics
    • Meters / Displays
    • Meter Kits
    • Gauges
    • Amplifiers
    • All EGT Electronics
  • EGT Accessories
    • Compression Fittings and Mounting Hardware
    • Connectors
    • Extension Wire
    • Weld Bungs
    • All EGT Accessories
  • CHT Sensors
    • Electronics
    • Accessories
    • All CHT Sensors
  • Gauges / Pyrometers
    • Single Channel
    • Multi-channel
    • All Gauges / Pyrometers
  • Gauge / Pyrometer Kits
    • Single Channel
    • Multi-channel
    • Round Digital Gauge Kits
    • Rectangular Digital Gauge Kits
    • Handheld Digital Gauge Kits
    • Round Analog Gauge Kits
    • Gas Engines Gauge Kits
    • Diesel Engine Gauge Kits
    • Marine Gauge Kits
    • Motor Home Gauge Kits
    • Snowmobile Gauge Kits
    • All Gauge / Pyrometer Kits
  • Belt Temperature
  • Brake Sensors
    • All Brake Sensors
  • Fluid Temperature
    • All Fluid Temperature
  • Linear Travel Sensors
  • Motorsports Tech Notes
    • EGT Tech Notes
      • Why Use our Probes?
      • Thermocouple Wire Color Chart
      • Thermocouple Compatibility List
      • EGT Probe Performance tuning Installation and Information
      • ITS-90 Thermocouple Correction Tables
      • What is a Thermocouple
      • EGT Diesel Engine Installation Information
    • CHT Tech Notes
  • Motorsports FAQ
    • EGT FAQs
    • CHT FAQs
  • Sale Items

Industrial Products

  • Thermocouples
    • Electronics
    • Accessories
    • All Thermocouples
  • RTDs
  • LVDT Position Sensors
    • Spring Loaded
      • AC
      • DC
      • 2-wire 4-20mA
    • Free Core
      • AC
      • DC
      • 2-wire 4-20mA
    • Accessories
    • All LVDT Position Sensors
  • LVDT Electronics
    • Electronics
    • All LVDT Electronics
  • Signal Conditioners
    • DC Input
      • DC Input to Alarms
      • DC Input to DC Output
      • DC Input to Frequency Output
    • Frequency Input
      • Frequency Input to Alarms
      • Frequency Input to DC Output
    • Strain Gauge / Load Cell Input
      • Strain Gauge Input to Alarms
      • Strain Gauge Input to DC Output
    • Temperature Input
      • Thermocouple Input to Alarms
      • Thermocouple Input to DC Output
      • RTD Input to Alarms
      • RTD Input to DC Output
    • All Signal Conditioners
  • Instrumentation
    • Meters / Displays
  • Rotary Sensors
    • Electronics
    • Accessories
    • All Rotary Sensors
  • Linear Position Sensors
  • Pressure Transducers
  • Suco Pressure Switches
  • Cable Assemblies
  • Custom Products
  • Industrial Tech Notes
    • LVDT Tech Notes
    • Signal Conditioner Tech Notes
    • Position Sensors Tech Notes
    • All Industrial Tech Notes
  • Industrial FAQ
    • LVDT FAQs
    • Signal Conditioner FAQs
    • Position Sensors FAQs
    • All Industrial FAQ
  • Sale Products

Find Sensors and Electronics by Application

  • Motorsports
    • Gas Racing
      • Racing Drag / Road/ Circle
      • Motorcycles / Drag / Road / Circle
      • Small Engines
    • Diesel & Bio Fuel
      • Trucks / Towing
      • Heavy Truck / Agricultural
      • Power Gen EGT
    • Marine
      • Marine Diesel
      • Marine Gas
    • Aircraft
      • Small Aircraft Engines
      • Ultralite
    • Commercial
      • Barbecue / Smokers
      • Flu / Heater / Furnaces
      • HVAC
  • Industrial
    • Factory Automation
    • Energy and Power Gen
    • Industrial OEM
    • Hydraulics / Pneumatics
    • Aerospace / Military
    • Civil Engineering

Technical Info

  • Manuals & Datasheets
    • LVDT
      • Catalogs
        • LVDT Short Form Catalogs
        • LVDT Full Detail Catalogs
    • EGT Probes
      • Catalogs
        • EGT Probe Short Form Catalogs
        • EGT Probe Full Detail Catalogs
  • Horsepower Calculators
    • Horsepower
    • Engine Displacement
  • Racing Weather
  • Blogs
    • LVDT Blog
    • EGT Probe Blogs
  • Videos

Corporate Info

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases
Home » Signal Conditioners

API 4300G - DC to DC Isolated Transmitter

API 4300 DC to DC Transmitter Module
Sale Price:
$329.00
SKU: API-4300G
Availability: 1 week
Quantity:

Options

Choose module power options

Choose module response time options

Add a Mountng Socket?

Product Info:

  • Summary
  • Technical
  • Video

• DC Voltage Input: 0-100 mV to 0-500 V
• DC Bipolar Voltage Input: +/- 100 mV to +/- 10 V
• DC Current Input 0-1 mA to 900 mA
• DC Output: 0-1 V, 0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 4-20 mA, etc.
• Factory Pre-Configured

Lead-time: Typically ships within 2 to 3 business days

CLICK on Technical Tab to download data sheet with full technical details

Made in the USA

Input
Factory Configured; Specify Input Range
Voltage: 0-100 mVDC to 0-500 VDC
or
Bipolar Voltage: +/- 100 mVDC to +/- 10 VDC
or
Current: 0-1 mADC to 0-900 mADC

Output
Factory Configured; Specify Output Range
Voltage: 0-1 VDC to 0-10 VDC
or
Bipolar Voltage: +/- 1 VDC to +/- 10 VDC
or
Current (20 V compliance): 0-1 mADC to 0-20 mADC

Isolation
Full 2000 Vrms Input/Output/Power Isolation

 

Features
Hot-swappable plug-in design
I/O LoopTracker LEDs
Output test button
18 V loop power supply
Uses API-008 8-pin socket
85 to 265 VAC powered
D option for 9-30 VDC power
DF option for Fast Response Time

Applications
Convert, boost, rescale process signals
Interface process signals with panel meters, recorders, recorders, data acquisition systems, PLCs, DCS & SCADA systems

Brand Name: API Absolute Process Instruments
Made in: USA

Datasheet:
application/pdf iconapi4300g-4310g.pdf

 

 
The API 4300 G and API 4310 G are factory configured to accept a DC voltage or current input and provide an optically isolated DC voltage or current output that is linearly related to the input. 
 
The API 4310 G utilizes an ultra-stable input amplifier for reliable operation with input signals as low as 10 mVDC. 
Typical applications include signal isolation, conversion, boosting or a combination of the three. Full 3-way isolation (input, output, power) makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.
 
When a milliamp input is specified, a loop excitation power supply is included that may be wired for sinking or sourcing to allow you to use a powered or passive input device.
 
When a milliamp output is ordered, it provides power to the output current loop (sourcing). If an unpowered (sinking) current output is required, order the API 4300 G EXTSUP with open collector output.
 
Common ranges as well as custom ranges are possible. 
 
Consult the factory for assistance with special ranges.

CUSTOMER WHO BOUGHT THIS PRODUCT ALSO BOUGHT

API 7010G - Frequency to DC Isolated Transmitter
API 7010G - Frequency to DC Isolated Transmitter

Choose module power options

Add a Mountng Socket?

Quantity:

Harold G. Schaevitz Industries LLC

The Sensor Connection

World Headquarters

43996 Woodward Avenue

Suite 200

Bloomfield Hills, MI 48302

Phone: 248-636-1515  

Fax: 248-636-4969

CORPORATE

  • Sitemap
  • About Us
  • Contact Us
  • Privacy Policy
  • Press Releases

MY ACCOUNT

  • Checkout
  • Login
  • Register
  • View Cart
© Copyright 2021.
All Rights Reserved.
PayPal
Credit Cards
 Network Solutions Seal
website by jhoward.org
[Jump to Top] [Jump to Main Content]