OVERVIEW
• EGT Probe Input: Type K Thermocouple (8 independent input channels)
• BONUS! On-board +/- 4g Accelerometer
• Linearized Analog Output: 0 to 5 VDC (9 independent output channels)
• Stream data to PC via USB (software included)
• Includes (8) mini-plug signal input connectors
• Includes detachable signal output/power wiring harness
• Compact Size, only 7.0" x 3.5" x 1.6"
• Onboard Accelerometer Measuring Range: +/- 4g
• Accelerometer Output Scale Factor: 1V / g
MADE IN THE USA
The Sensor Connection TCA-IND-U-8-A4 EGT Probe Thermocouple Amplifier Module functions to convert the low output voltage signal from up to 8 Type K thermocouple EGT probes into 8 independent linearized 0 to 5 VDC output voltages. This output is ideal for interfacing to dataloggers, aftermarket ECU's, temperature indicators, chart recorders, controllers, or other motorsports instrumentation equipment.
Setup of the TCA-IND-U-8-A4 is simple using the included Windows programming software. The software also allows for data logging to an attached PC. The Amplifier interfaces to the PC via USB.
Also includes an onboard single-axis +/- 4g capacitive accelerometer for measuring acceleration and brake events.
IMPORTANT DISCLAIMER IF YOU ARE CONSIDERING USING THIS INSTRUMENT IN AN AIRCRAFT:
This instrument is not certified by the FAA. Fitting of this instrument to certified aircraft is subject to the rules and conditions pertaining to such in your country. Please check with your local aviation authorities if in doubt. This instrument is intended for ultralight, microlight, homebuilt and experimental aircraft. Operation of this instrument is the sole responsibility of the pilot in command (PIC) of the aircraft. This person must be proficient and carry a valid and relevant pilot’s license. This person has to make themselves familiar with the operation of this instrument and the effect of any possible failure or malfunction. Under no circumstances does The Sensor Connection or manufacturer condone usage of this instrument for IFR flights.
Options:
TECHNICAL SPECIFICATIONS
Number of Inputs: |
8 |
Input: |
K, J, or T type thermocouple (ungrounded) |
Input Resistance: |
60k Ω |
Max Bias Voltage on Input: |
5.8 V |
Thermocouple Measuring Range: |
User selectable |
Input Connection: |
Mini Thermocouple Jack |
Number of Output Channels: |
9 total (8 for Thermocouple Channels, 1 for Accelerometer) |
Analog Output Range: |
0 to +5 VDC |
Accelerometer Output Scale Factor (nominal) |
625 mV / g |
Resolution: |
0.0625V |
Response Time: |
> 10 mS |
Humidity: |
85% Max. RH (non-condensing) |
Output Cable: |
12 conductor, 22 AWG, PVC jacket, 3 foot long (detachable) |
Supply Voltage: |
10 to 32 VDC |
Current Draw: |
< 50 mA |
Operating Temperature Range: |
+32 to +125°F (0 to +50°C) |
Liquid & Dust Protection: |
IP51 |
Housing Dimensions (L x W x H): |
7.0 x 3.5 x 1.6 inch |
Weight: |
0.6 lb (265 g) |